欢迎访问《金属矿山》杂志官方网站,今天是 分享到:
×

扫码分享

金属矿山 ›› 2026, Vol. 55 ›› Issue (4): 229-236.

• 安全与环保 • 上一篇    

火源位置与通风量对金属矿山漏风巷道火灾及疏散的影响#br#

梁维康1,2,3  马小龙1,2,3  贾敏涛1,2,3  何 顺1,2,3  周 伟1,2,3  赵 旭1,2,3   

  1. 1. 中钢集团马鞍山矿山研究总院股份有限公司,安徽 马鞍山 243000;2. 金属矿山开采安全与灾害防治全国重点实验室,
    安徽 马鞍山 243000;3. 金属矿产资源高效循环利用国家工程研究中心,安徽 马鞍山 24
  • 出版日期:2026-04-15 发布日期:2026-05-09
  • 通讯作者: 马小龙(1988—),男,高级工程师。
  • 作者简介:梁维康(1999—),男,工程师。
  • 基金资助:
    “十四五”国家重点研发计划项目(编号:2023YFC2907205)。

Effects of Fire Location and Ventilation Rate on Smoke Spread and Evacuation in Leaky Roadways of Metal Mines#br#

LIANG Weikang1,2,3  MA Xiaolong1,2,3  JIA Mintao1,2,3  HE Shun1,2,3  ZHOU Wei1,2,3  ZHAO Xu1,2,3   

  1. 1. Sinosteel Maanshan General Institute of Mining Research Co. ,Ltd. ,Maanshan 243000,China;
    2. State Key Laboratory of Metal Mine Mining Safety and Disaster Prevention and Control,Maanshan 243000,China;
    3. National Engineering Research Center for Efficient Recycling of Metallic Mineral Resources,Maanshan 243000,China
  • Online:2026-04-15 Published:2026-05-09

摘要: 矿井巷道中普遍存在联络巷及漏风通道,火灾发生后烟气在风流与漏风作用下传播路径复杂,对人员
安全疏散产生影响。为分析漏风条件下金属矿山巷道火灾烟气扩散及人员疏散规律,以某金属矿山-568 m 水平巷道
为研究对象,采用PyroSim 与Pathfinder 耦合模拟方法,对不同火源位置及通风量条件下的烟气扩散特征及人员疏散
过程进行数值分析。结果表明:火源位置对人员疏散时间影响显著,当火源靠近主巷及人员集中区域时,烟气更易进
入主要疏散通道并形成长距离低能见度区域,从而明显降低疏散效率;在13. 46~26. 46 m3 / s 通风量范围内,烟气空间
分布特征变化较小,人员疏散时间对通风量变化不敏感。漏风通道的存在改变了烟气传播路径,并在局部区域形成
烟气滞留或回流现象。研究结果可为金属矿山漏风巷道火灾风险评估及应急疏散组织提供参考。

关键词: 金属矿山火灾 , 漏风巷道 , 烟气扩散 , 火源位置 , 人员疏散

Abstract: Contact lanes and air leakage channels are common in mine roadways. After the fire,the propagation path of
smoke under the action of airflow and air leakage is complex,which has an impact on the safe evacuation of personnel. In order
to analyze the law of fire smoke diffusion and personnel evacuation in metal mine roadway under air leakage conditions,the -
568 m horizontal roadway of a metal mine was taken as the research object,and the coupling simulation method of PyroSim and
Pathfinder was used to numerically analyze the smoke diffusion characteristics and personnel evacuation process under different
fire source locations and ventilation conditions. The results show that the location of the fire source has a significant effect on
the evacuation time. When the fire source is close to the main lane and the area where people are concentrated,the smoke is
more likely to enter the main evacuation channel and form a long-distance low-visibility area,thus significantly reducing the evacuation
efficiency. In the range of 13. 46 ~ 26. 46 m3 / s ventilation rate,the spatial distribution characteristics of smoke
change little,and the evacuation time is not sensitive to the change of ventilation rate. The existence of the air leakage channel
changes the flue gas propagation path and forms the phenomenon of flue gas retention or backflow in the local area. The research
results can provide reference for fire risk assessment and emergency evacuation organization of air leakage roadway in
metal mines.

Key words: metal mine fires,air leakage roadway,smoke diffusion,fire source location,evacuation

中图分类号: