欢迎访问《金属矿山》杂志官方网站,今天是 分享到:

金属矿山 ›› 2018, Vol. 47 ›› Issue (12): 19-26.

• 采矿工程 • 上一篇    下一篇

钢筋混凝土假顶力学模型构建与参数优化

杜永亮   

  1. 赤峰山金红岭有色矿业有限责任公司,内蒙古 赤峰 025454
  • 出版日期:2018-12-15 发布日期:2019-01-17
  • 基金资助:

    基金项目:国家自然科学基金项目(编号:51674288)。

The Mechanical Mode Construction and Parameter Optimization for False Roof of Reinforced Concrete

Du Yongliang1   

  1. Shandong Gold Mining (Hongling) Co., Ltd., Chifeng 025454, China
  • Online:2018-12-15 Published:2019-01-17

摘要: 利用钢筋混凝土材料构筑大跨度、高阶段采场的人工假顶是嗣后充填开采的一个新工艺,但钢筋混凝土造价高,有必要研究确定合理的钢筋混凝土假顶强度、厚度和配筋参数。针对内蒙古某铅锌矿高阶段嗣后充填开采人工假顶暴露跨度大、采场高度大的技术特征,将钢筋混凝土假顶力学模型简化为薄“板”理论模型和简支“梁”理论模型,得出钢筋混凝土假顶安全系数随厚度增加呈二次函数升高,揭示了钢筋混凝土假顶强度、安全系数与厚度之间的演化规律。并采用经济配筋率理论和FLAC3D软件确定了大跨度钢筋混凝土假顶厚度为1.5 m、强度为20.0 MPa、配筋参数为[?]25 mm×95 mm。研究结果显示,钢筋混凝土假顶在其自重及上部充填体作用下处于稳定状态,验证了所留设钢筋混凝土假顶厚度以及配筋设计的合理性,指导了矿山钢筋混凝土假顶设计。

关键词: 嗣后充填, 钢筋混凝土假顶厚度, 薄板理论, 简支梁理论, 数值模拟, 经济配筋率

Abstract: It is a new technique of mining with subsequent backfilling that the artificial false roof of reinforced concrete is in large exposure span and high stope height. However, the false roof of reinforced concrete costs high, so it is necessary to determine the reasonable parameters of strength, thickness, and reinforcement ratio of the false roof. In view of the technical features of the false roof with large exposure span and high stope height at high-stage subsequent backfilling stoping in a lead-zinc mine of Inner Mongolia, the mechanical models of false roof of reinforced concrete was simplified into thin plate and simply supported beams theory models, obtaining that the safety ratio of false roof of reinforced concrete increases in polyno-mials with the increase of the thickness of false roof of reinforced concrete. The laws between the strength of concrete, the safety ratio, and the thickness of false roof were revealed. Using economic reinforcement ratio theory and FLAC3D software, the optimum thickness of the false roof of reinforced concrete is determined as 1.5 m, the strength as 20.0 MPa ,and the reinforcement parameter as [?]25 mm×95 mm. The research result showed that the reinforced concrete false roof can be in a stable state under the action of its self weight and the upper filling body, which verify the reasonabilty of the thickness of the false roof and the reinforcement parameters. It guides the design of false roof of reinforced concrete in underground mine.

Key words: Subsequent backfill, Thickness of false roof with reinforced concrete, Theory of thin plates, Theory of simply supported beams, Numerical simulation, Economic reinforcement ratio