As(Ⅲ) Removal in Water by Fenton Oxidation-Flocculation Method

Li Fuping1,Duan Wulin2,Luo Xiaoyan2   

  1. 1.Jiangxi College of Applied Technology,Ganzhou 341000,China;2.Excellence Utilization of Renewable Resources Co.Ltd.,Ganzhou 341700,China
  • Online:2017-06-15 Published:2017-09-27

Abstract: With the deterioration of groundwater arsenic pollution problem,arsenic pollution has become an issue of common concern in the world.To seek for the economic and reasonable arsenic removal technology,Fenton reagent oxidation-flocculation method is used for As (Ⅲ) removal test.Initial wastewater As (Ⅲ) concentration is 0.5 mg/L,optimum arsenic removal condition ensured in experiment is regulating wastewater initial pH=3.0,H2O2 dosage of 10 mg/L,mole ratio of Fe2+ to H2O2 is 0.2,reaction time is 10 min,As (Ⅲ) removal rate was 95.17%.Adopt the best conditions for a actual arsenic bearing wastewater from Ganzhou removal test showed that the As (Ⅲ)) removal rate can reach 94.71%,As(Ⅲ) concentration in water is 0.0042 mg/L,below the standard of 0.01 mg/L in drinking water health standards (GB5749-2006).Fenton oxidation-flocculation arsenic removal is a method using intermediate (including H2O2,·OH,O2·,·HO2,etc.) produced in Fenton reaction to flocculation combined As (Ⅲ) and iron salt.