Application of Ultra-High Density Resistivity Method in Detection of Water Level of Tailings Reservoir

Zhao Kui1,2,Wu Yuesheng3,Gao Zhong3,Wang Ming3   

  1. 1.Engineering Institute,Jiangxi University of Science and Technology;2.Engineering Research Center of High-efficiency Development and Application Technology of Tungsten Resources,Ministry of Education;3.Faculty of Resource and Environmental Engineering,Jiangxi University of Science and Technology
  • Online:2013-11-15 Published:2014-01-26

Abstract: The ultra-high density resistivity method was applied to detect the water level of tailing reservoirBased on this,it is proposed that the water lever of tailing reservoir is determined according to the actual changing rate of electronic resistivityThen the water level obtained is compared with the actual result by the field drillingThe result shows that the detected result is basically in line with the actual water level measured through the field drilling,which provides a new method for the water level measurement of tailing reservoirs.