Metal Mine ›› 2015, Vol. 44 ›› Issue (04): 44-47.
Previous Articles Next Articles
Yang Zhu,Wang Jun,Zhao Qia
Online:
Published:
Abstract: Due to the complex aquifer-medium among structural fissured water-rich deposits,there are great difficulties in construction and high risk of water gushing-out,so it is hard to realize the water prevention and control.As a reference from the water control experiences of water-rich deposit in karst,the curtain grouting technology for water control at the surface of mine is adopted to treat the groundwater disaster in fissured water-rich deposit at tectonic volcanic rocks in Huangtun pyrites.According to the full-scale test of curtain grouting,and through analyzing water permeability of curtain-grouting before and after grouting,the water pressure test,the drilling core exposure before and after grouting,it is proved that after the high-pressure grout injection for fractured formation in volcanic rocks,water-conducting channel with large structure and micro-fractures can be effectively filled,with remarkable grouting effect.So,this method can be as a reference for the same type of deposit.
Key words: Tectonic fissured water-rich deposit, Curtain grouting test, Grouting parameter
YANG Zhu, WANG Jun, ZHAO Qia. Test and Parameters of Curtain Grouting for the Tectonic Fissured Water-rich Deposits[J]. Metal Mine, 2015, 44(04): 44-47.
/ Recommend